Abstract
In contrast to common 3-phase topologies, DC-link capacitance can be reduced by combining input
power after the DC-link using a multi-port transformer and suitable control. Initial results of this approach
demonstrate stable 12 kW output power using only 5 μF DC-link capacitance per phase, promising
higher power density and reliability. Furthermore, a novel control scheme is proposed that allows
high frequency reactive power flow through the multi-port transformer to be manipulated via gate-signal
phase angles, in order to achieve maximum efficiency and minimum DC-link voltage ripple for any load
condition.
power after the DC-link using a multi-port transformer and suitable control. Initial results of this approach
demonstrate stable 12 kW output power using only 5 μF DC-link capacitance per phase, promising
higher power density and reliability. Furthermore, a novel control scheme is proposed that allows
high frequency reactive power flow through the multi-port transformer to be manipulated via gate-signal
phase angles, in order to achieve maximum efficiency and minimum DC-link voltage ripple for any load
condition.
Originalsprache | englisch |
---|---|
DOIs | |
Publikationsstatus | Veröffentlicht - 11 Sept. 2020 |
Veranstaltung | 22nd European Conference on Power Electronics and Applications: EPE 2020 ECCE Europe - Lyon, Frankreich Dauer: 7 Sept. 2020 → 11 Sept. 2020 https://epe-ecce-conferences.com/epe2020/ |
Konferenz
Konferenz | 22nd European Conference on Power Electronics and Applications |
---|---|
Kurztitel | EPE'20 ECCE Europe |
Land/Gebiet | Frankreich |
Ort | Lyon |
Zeitraum | 7/09/20 → 11/09/20 |
Internetadresse |
Schlagwörter
- DC-Link capacitance
- Multiport LLC
- 3 phase onboard charger
ASJC Scopus subject areas
- Steuerung und Optimierung
- Sicherheit, Risiko, Zuverlässigkeit und Qualität
- Energieanlagenbau und Kraftwerkstechnik
- Elektrotechnik und Elektronik
Fields of Expertise
- Mobility & Production