Pressure Pulsation of a Single-stage Storage Pump with 1300 m Delivery Head

Helmut Benigni*, Stefan Leithner, Peter Meusburger, Christian Bodner, Helmut Jaberg, David Gieffing, Gerhard Penninger, Christian Kirilowitsch, Andreas Prackwieser, Martin Giese

*Korrespondierende/r Autor/-in für diese Arbeit

Publikation: Beitrag in einer FachzeitschriftKonferenzartikelBegutachtung

Abstract

A new storage pump replaced 3 multistage pumps to transport water between the Kreuzeck and the Reisseck power plant sides. Located in the valley of the two reservoirs, it provides impressive performance data for single-stage operation at n = 3000 rpm. Hydraulics already utilised for significantly lower heads are the basis of this pump. The pump was adapted to the new location, and CFD-based development was applied. Within the scope of a model test, the performance data (Q-H-Eta and Q-H-Sigma) were to be confirmed and measured, including the inflow and outflow situation. In addition, the pressure pulsations had to be verified. Finally, installing air vessels should reduce pressure pulsations on the suction and pressure sides. Furthermore, modifications in the bladed areas of the impeller and the guide vane section should enhance this reduction
Originalspracheenglisch
Aufsatznummer012041
FachzeitschriftIOP Conference Series: Earth and Environmental Science
Jahrgang1079
DOIs
PublikationsstatusVeröffentlicht - 1 Juli 2022
Veranstaltung31st IAHR Symposium on Hydraulic Machinery and Systems - NTNU, Trondheim, Norwegen
Dauer: 27 Juni 20221 Juli 2022

ASJC Scopus subject areas

  • Energie (insg.)
  • Maschinenbau

Fields of Expertise

  • Sustainable Systems

Treatment code (Nähere Zuordnung)

  • Application

Fingerprint

Untersuchen Sie die Forschungsthemen von „Pressure Pulsation of a Single-stage Storage Pump with 1300 m Delivery Head“. Zusammen bilden sie einen einzigartigen Fingerprint.

Dieses zitieren