Very large and giant microsurgical bifurcation aneurysms in rabbits: Proof of feasibility and comparability using computational fluid dynamics and biomechanical testing

Camillo Sherif*, Erwin Herbich, Roberto Plasenzotti, Helga Bergmeister, Ursula Windberger, Georg Mach, Gerhard Sommer, Gerhard Holzapfel, Thomas Haider, Martin Krssak, Guenther Kleinpeter

*Korrespondierende/r Autor/-in für diese Arbeit

Publikation: Beitrag in einer FachzeitschriftArtikelBegutachtung

Abstract

Background
Giant aneurysms are challenging lesions with unacceptable high rates of aneurysm recanalization and rerupture following embolization. Reliable in vivo models are urgently needed to test the performance of new more efficient endovascular devices.
Materials and methods
Aneurysms were created in 11 New Zealand white rabbits (4.5–5.5 kg): A long venous pouch (length 25–30 mm) mimicking the aneurysm sac was derived from the external jugular vein and sutured into a microsurgically created bifurcation between both common carotid arteries. After 4 weeks the rabbits underwent 3 T Magnetic resonance angiography (3T-MRA). Exemplary computational fluid dynamics (CFD) simulations were performed to compare the flow conditions of giant rabbit and human aneurysms. We used species-related boundary conditions, in particular, we measured blood viscosity values. Biaxial mechanical tests were performed for the mechanical characterization and comparison.
Comparison with exisiting method(s)
None.
Results
No peri- or postoperative mortality was observed. 3T-MRA showed aneurysm patency in 10 out of 11 aneurysms (90.9%). Aneurysm lengths ranged from 21.5–25.6 mm and aneurysm necks from 7.3–9.8 mm. CFD showed complex flow profiles with multiple vortices in both, rabbit and human aneurysms. Lower blood viscosity values of the rabbit (3.92 mPa s vs. human 5.34 mPa s) resulted in considerable lower wall shear stress rates (rabbit 0.38 Pa vs. human 1.66 Pa). Mechanical tests showed lower stiffness of rabbit aneurysms compared to unruptured human aneurysms.
Conclusions
The proposed model showed favorable aneurysm patency rates, low morbidity and good hemodynamic comparability with complex flow patterns. Biomechanical testing suggests that experimental aneurysms might be even more fragile compared to human aneurysms.
Originalspracheenglisch
Seiten (von - bis)7-13
FachzeitschriftJournal of Neuroscience Methods
Jahrgang268
DOIs
PublikationsstatusVeröffentlicht - 2016

Fingerprint

Untersuchen Sie die Forschungsthemen von „Very large and giant microsurgical bifurcation aneurysms in rabbits: Proof of feasibility and comparability using computational fluid dynamics and biomechanical testing“. Zusammen bilden sie einen einzigartigen Fingerprint.

Dieses zitieren