Abstract
Twenty Radiated emission sites are compared using a sinusoidal reference transmitter in the frequency range of 30 to 1000 MHz. The data is referenced to results measured on the UK National Physical Laboratory and Austrian Research Centers reference sites. The data on nineteen sites is reported in this article, the data on the one remaining was done at three meters and not comparable. Of the nineteen sites, nine performed from four to six measurements on different days and usually with different people. Statistically, the results of these nine sites show 95% of the measurements made were within +/-2.1 dB from the average of the reference sites. Test result differences in repeated EMC tests are partially caused by physical characteristics of the measurement sites and changes or differences in the measurement chain. This program has met the requirements of A2LA and NVLAP for site-to-site comparisons. Being programmable the source could be easily adaptable to `blind' proficiency assessments.
Original language | English |
---|---|
Pages (from-to) | 939-943 |
Number of pages | 5 |
Journal | IEEE International Symposium on Electromagnetic Compatibility |
Volume | 2 |
Publication status | Published - 1 Jan 2000 |
Externally published | Yes |
Event | 2000 IEEE International Symposium on Electronic Compatibility - Washington, DC, USA Duration: 21 Aug 2000 → 25 Aug 2000 |
ASJC Scopus subject areas
- Condensed Matter Physics
- Electrical and Electronic Engineering