Abstract
Open-switch faults in inverter-driven electric drives have recently gained increasing attention in the scientific community. Since these faults may lead to undesired effects, their fast and unambiguous detection is desirable. This paper proposes a detection algorithm for open-switch faults, which is based on the observation of the current control deviation and a subsequent test procedure. This algorithm detects the fault immediately after its occurrence within a few switching periods, even during transient operation. The proposed method is tested via simulations and experiments at different operating points of a surface permanent magnet drive.
Originalsprache | englisch |
---|---|
Seiten (von - bis) | 5415-5425 |
Fachzeitschrift | IEEE Transactions on Industry Applications |
Jahrgang | 53 |
Ausgabenummer | 6 |
DOIs | |
Publikationsstatus | Veröffentlicht - 2017 |