Abstract
Voltage dips caused by faults in the power supply, change the behavior of single phase induction machines because transient currents and torques occur. In order to find an optimal disconnecting and restart time, the effects on the machine and the process must be determined. The effects of such voltage dips on the transient behavior depend on the chosen start circuit of the machine. In this paper the effects of different voltage dips and load conditions are analyzed by 2D-FEM calculations. First, the 2D-FEM results are compared with the results of measurements on a motor test stand. Different strategies of restarting are
derived from the analyzed results and the chosen start circuit of the machine.
derived from the analyzed results and the chosen start circuit of the machine.
Original language | English |
---|---|
Pages | 452 |
Number of pages | 457 |
Publication status | Published - 2016 |
Event | Power Electronics, Electrical Drives, Automation and Motion - Capri, Italy Duration: 22 Jun 2016 → 24 Jun 2016 |
Conference
Conference | Power Electronics, Electrical Drives, Automation and Motion |
---|---|
Abbreviated title | SPEEDAM 2016 |
Country/Territory | Italy |
City | Capri |
Period | 22/06/16 → 24/06/16 |