Accelerated 2D Cartesian MRI with an 8-channel local B0 coil array combined with parallel imaging

Rui Tian*, Martin Uecker, Mathias Davids, Axel Thielscher, Kai Buckenmaier, Oliver Holder, Theodor Steffen, Klaus Scheffler

*Korrespondierende/r Autor/-in für diese Arbeit

Publikation: Beitrag in einer FachzeitschriftArtikelBegutachtung

Abstract

Purpose: In MRI, the magnetization of nuclear spins is spatially encoded with linear gradients and radiofrequency receivers sensitivity profiles to produce images, which inherently leads to a long scan time. Cartesian MRI, as widely adopted for clinical scans, can be accelerated with parallel imaging and rapid magnetic field modulation during signal readout. Here, by using an 8-channel local (Formula presented.) coil array, the modulation scheme optimized for sampling efficiency is investigated to speed up 2D Cartesian scans. Theory and Methods: An 8-channel local (Formula presented.) coil array is made to carry sinusoidal currents during signal readout to accelerate 2D Cartesian scans. An MRI sampling theory based on reproducing kernel Hilbert space is exploited to visualize the efficiency of nonlinear encoding in arbitrary sampling duration. A field calibration method using current monitors for local (Formula presented.) coils and the ESPIRiT algorithm is proposed to facilitate image reconstruction. Image acceleration with various modulation field shapes, aliasing control, and distinct modulation frequencies are scrutinized to find an optimized modulation scheme. A safety evaluation is conducted. In vivo 2D Cartesian scans are accelerated by the local (Formula presented.) coils. Results: For 2D Cartesian MRI, the optimal modulation field by this local (Formula presented.) array converges to a nearly linear gradient field. With the field calibration technique, it accelerates the in vivo scans (i.e., proved safe) by threefold and eightfold free of visible artifacts, without and with SENSE, respectively. Conclusion: The nonlinear encoding analysis tool, the field calibration method, the safety evaluation procedures, and the in vivo reconstructed scans make significant steps to push MRI speed further with the local (Formula presented.) coil array.

Originalspracheenglisch
Seiten (von - bis)443-465
Seitenumfang23
FachzeitschriftMagnetic Resonance in Medicine
Jahrgang91
Ausgabenummer2
DOIs
PublikationsstatusVeröffentlicht - Feb. 2024

ASJC Scopus subject areas

  • Radiologie, Nuklearmedizin und Bildgebung

Kooperationen

  • BioTechMed-Graz

Fingerprint

Untersuchen Sie die Forschungsthemen von „Accelerated 2D Cartesian MRI with an 8-channel local B0 coil array combined with parallel imaging“. Zusammen bilden sie einen einzigartigen Fingerprint.

Dieses zitieren